One potential scenario would be to accidentally connect to the wrong processor, and then to start forcing its I/O signals – or making modifications to its program code. The flexibility of this type of operation can be a major advantage – but it can also be extremely dangerous. The ControlLogix and the CompactLogix platforms have a powerful feature that allows you to connect your computer through a communications cable – then “drill down” to the chassis backplane – and then access any processor connected to the system by a network cable. The trickiest (and the most dangerous) part for many technicians is tracking down the correct PLC processor on the RSLinx navigation screen.
#Rslinx classic driver
In most day-to-day situations, you’ll just make sure that the appropriate “driver” has been configured correctly in RSLinx, and then use the RSLogix-5000 software to access that driver and go “online” with the correct PLC processor.
![rslinx classic rslinx classic](https://uploads-ssl.webflow.com/5f7b0ab7d260466bdef601fa/61147a1eb7b7737ce1d7c46d_RSLinx_Classic_USB.png)
#Rslinx classic how to
The hard truth of the matter is that unless RSLinx is set up and configured correctly, then you will not be able to connect to the PLC to monitor its operation – or to do any online troubleshooting.Īs shown in the graphic on the left, there are a lot of “bells and whistles” available, but we’ll teach you how to interpret those. Despite the cute spelling, the basic idea is that this software “links” your computer to the PLC. The easiest way to think about RSLinx Classic is something like a “Communication Central” type of software package. Our Automation Specialists are knowledgeable resources, ready to provide informed answers and give expert recommendations.RSLinx Classic – required to communicate with your PLC RSLinx Rebranding and BeyondĪs an authorized Rockwell Automation distributor, we’re your go-to source for questions on RSLinx, FactoryTalk, and everything automation related.
#Rslinx classic professional
Distributed and Professional versions support 32000 and unlimited tags, respectively, in a networked FactoryTalk distributed model.
#Rslinx classic Pc
Basic and Standard support 10 tags, respectively, and the client must reside on the same PC as FactoryTalk Linx Gateway. FactoryTalk Linx Gateway products include Basic, Standard, Distributed, and Professional. Slight Name Change: FactoryTalk Linx GatewayįactoryTalk Linx Gateway, formerly called FactoryTalk Gateway, uses FactoryTalk Linx and serves Live Data to OPC DA and, now, OPC UA third-party clients. Live Data is the communication protocol used in the FactoryTalk suite of software products. Through FactoryTalk services, it delivers data to FactoryTalk-enabled applications via Live Data. FactoryTalk Linx takes data from Rockwell Automation controllers. …is Now FactoryTalk LinxįactoryTalk Linx, formerly called RSLinx Enterprise, is the preferred data server for Rockwell Automation FactoryTalk-enabled products. Lite versions were bundled with editors like RSLogix 5/500/5000 and Studio 5000 at no charge with. RSLinx Enterprise shipped with FactoryTalk-enabled software at no additional charge whereas RSLinx data servers were purchased separately for client software needing OPC or DDE access to Allen-Bradley® PLCs. RSLinx Enterprise was the product for communicating with FactoryTalk®-enabled products supporting the FactoryTalk Live Data system, a superset of OPC used by FactoryTalk software products like FTViewSE and FTHistorian. All versions have Lite functionality included. Gateway supports remote OPC clients and multiple controllers. Both Single Node and OEM must reside on the same PC as the client software. Single node is limited to one controller while OEM allows multiple controllers. RSLinx Classic Lite does not support OPC, whereas the other three versions are DDE/OPC servers.
#Rslinx classic free
The Lite version supports upload/download to Rockwell Automation controllers, is included with the purchase of RSLogix, and is a free download. It is available in four versions: Lite, Single Node, OEM and Gateway. Today, RSLinx Classic is still named RSLinx Classic and can be used for the purposes for which it was originally developed. This is also the communication product RSLogix editors have used to upload/download to controllers and IO. RSLinx Classic is an OPC DA 2.x data server and is required for DDE and bridging through legacy networks like DH+. Let’s look at what RSLinx rebranding means. Recently, Rockwell Automation® rebranded RSLinx® Enterprise to differentiate RSLinx Classic from RSLinx Enterprise.